SATEL INTEGRA Plus 99
• Description of DO NOT REPORT SATEL SERVER CONNECTION TROUBLE option
has been added (p. 73).
• Name of the D
O NOT REPORT TIME SERVER TROUBLE option has been changed
to D
O NOT REPORT TIME SERVER CONNECTION TROUBLE (p. 74).
• Name of the S
HOW ENTRY DELAY OF PARTITIONS parameter has been changed
to D
ISPLAY ENTRY DELAY OF PARTITIONS (p. 77).
• Name of the S
HOW EXIT DELAY OF PARTITIONS parameter has been changed to
D
ISPLAY EXIT DELAY OF PARTITIONS (p. 77).
• Description of S
IGNAL ENTRY DELAY OF PARTITIONS parameter has been added
(p. 77).
• Description of S
IGNAL EXIT DELAY OF PARTITIONS parameter has been added
(p. 77).
• Name of the D
O NOT REPORT SMTP SERVER TROUBLE option has been
changed to D
O NOT REPORT SMTP SERVER CONNECTION TROUBLE (p. 94).
2018-06 1.18
• List of functions available in the service mode menu has been supplemented
(p. 6-25).
• Information on the required version of DLOADX program has been modified
(p. 27).
• Section “Ethernet communication parameters” has been modified and
supplemented (p. 31).
• Section “GPRS communication parameters” has been modified and
supplemented (p. 33).
• Section “Starting remote programming via Ethernet network” has been
modified and supplemented (p. 38).
• Section “Starting remote GPRS programming” has been modified and
supplemented (p. 40).
• Description of 97. F
IRE PANEL FAULT. MONIT. zone type has been added (p. 54)
• Description of E
VENT: ARMING FAILED option has been added (p. 56).
• Description of R
EPORTING – GPRS option has been modified (p. 68).
• Description of R
EPORTING – ETHM option has been modified (p. 68).
• Description of R
EPORTING – ETHM/INT-GSM option has been added (p. 68).
• Description of SMS
MESSAGING option has been modified (s. 68).
• Note regarding SMS
MESSAGING option has been added (p. 68).
• Description of E-
MAIL MESSAGING option has been modified (p. 68).
• Description of M
ODEM ISDN/GSM/ETHM option has been modified (p. 69).
• Description of A
NSWERING - ETHM/GSM option has been modified (p. 69).
• Description of D
O NOT REPORT LAN LOSS ON AC LOSS option has been added
(p.
73).
• Description of N
O ARMED INDICATION AFTER option has been modified (p. 73).
• Description of T
IME SERVER option has been modified (p. 74).
• Description of C
ARD READER FILTER parameter has been modified (p. 79).
• Section “Reporting” has been modified and supplemented (p. 83).
• Section “Messaging” has been modified and supplemented (p. 91).
2019-05 1.19
• Information about ABAX 2 system devices has been added.
• List of functions available in the service mode menu has been supplemented
(p. 6-25).
• Information on the required version of DLOADX program has been modified
(p. 27).
• Description of R
EPORTING DELAY option has been modified (p. 57).
• Description of 83. O
UTPUTS OFF type output has been modified (p. 62).
• Description of 120. T
HERMOSTAT type output has been modified (p. 64).
• Description of ON/OFF option has been added (p. 65).
• Description of T
EMPERATURE DETECTOR parameter has been modified (p. 66).
• Description of H
YSTERESIS parameter has been modified (p. 66).