Section 3: Operation and Configuration
Page 3-26 CG2 Series Operator Manual
3.15 PROTECTION FUNCTION WHEN USING AC ADAPTER
When the print ratio per label exceeds the ratio shown in the table below, print job is paused temporarily
because of the protective pause function.
• The protection function (pause function) will be activated when the print ratio exceeds the ratio listed in the
table below.
• Print pause duration differs depending on print ratio, print speed and pitch size. The table below shows the
pause duration when the print speed is 3 inch/sec and the pitch size is 80mm.
Model
Print speed
2 inch/sec 3 inch/sec 4 inch/sec
CG208DT/TT 44% 35% 31%
CG212DT/TT 43% 38% 36%
Model
Print ratio
40% 50% 60% 70% 80%
CG208DT/TT 120 ms 417 ms 713 ms 1010 ms 1307 ms
CG212DT/TT 55 ms 335 ms 615 ms 896 ms 1176 ms
Print start
Print ratio check (exceed
the print ratio limits?)
Protection function
activated
Print is paused
ON LINE (POWER)
Print restart
No
Yes
Red→Green→Off