EasyManuals Logo

SATO CG2 Series User Manual

SATO CG2 Series
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
Section 3: Operation and Configuration
CG2 Series Operator Manual Page 3-25
3.14 HEAD OVER-TEMPERATURE PROTECTION
When the head temperature exceeds 70 ºC (158 ºF), the head over-temperature protection will be activated
and the print operation will be paused until the temperature drops down to 55 ºC (131 ºF).
* Head temperature will be checked per label.
Print start
Recheck head temperature
(Lower than 55 ºC, 131 ºF?)
Head over-temperature
protection activated
Ongoing print operation
will be paused
ON LINE (POWER)
Print operation will
occur when the head
temperature
becomes lower than
70
º
C (158
º
F).
No print operation will
occur unless the
head temperature
becomes lower than
50
º
C (131
º
F).
Print processing
Recheck per
label
No
No
Yes
Yes
Green→Red→Off
Head temperature check
(Higher than 70 ºC, 158 ºF?)