EasyManua.ls Logo

SBC PCD2.M5 Series - Modem Module for I;O Module Socket

SBC PCD2.M5 Series
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Manual for the PCD2.M5 Series│Document 26/856; Version EN 12│2014-07-24
Saia-Burgess Controls AG Communication interfaces
5
5-24
Modem communication
5.6 Modem module for I/O module socket
PCD2.T814:
analogue modem 33.6 kbps
(RS-232andTTLinterface)
PCD2.T851:
digital modem ISDN-TA
(RS-232andTTLinterface)
Recommended slots for connection using ribbon cable:
PCD2.M5_-Slot#4(recommended)
If a different socket is chosen for the internal modem, it can no longer be connected
viatheribboncable.ThemodemisthenconnectedtothePCD7.F121interface
modulebyspringterminals.anual26/771“PCD2.T8xxmodemmodules“
AnexternalmodemcanalsobeconnectedtothePCD7.F121module.
Forphysicalreasons,PCD2.T8xxmodemscannotbeconnectedtotheslots
highlighted in colour:
PCD2.Mxxxx
#0 #1 #2 #3
#4#5#6#7
Not allowed Slot
Two modem modules cannot be mounted side-by-side.
Forinstalltiondetails,seemanual26/771“PCD2.T8xxmodemmodules“
Do not use the modem modules on PCD2.C2000/C1000.

Table of Contents