4.2 DAQlink III Configuration Standard menus
When first installed, the Vscope program uses Standard menus. These menus provide all
of the necessary options for normal seismic operation. The Advance menus are selected in the
Option – Preferences –Menu.
It is important on new installations to check the DAQ settings. Click the “Device button”
on the Tool bar and the DAQlink Configuration Menu should appear. This will also check that
communication to the DAQlink III unit is working properly. If the configuration window does
not appear, it means that the DAQlink III unit selected is not responding. This is usually caused
by improper TCP/IP settings, or Ethernet cable not plugged in properly. The computer or
DAQlink III unit may need to be reset if the TCP/IP configuration has changed.
An additional check of communication can be performed by first removing all DAQ units
from the DAQ setup table. Highlight the DAQ unit to be removed then press the Remove button.
After all units have been removed, press the Auto Detect button and all units connected to the
computer will be added.