89
Acquiring Refraction data with Hammer Hits
Press “Ctrl R” to enable the “Repeat Start” or “Auto Start” function of the system
Press “A” – Starts Auto Sequence
Wait for Real Time Noise Monitor to show Low Noise – (Press “N” to enable the
real time Noise Feature)
Hit Strike Plate with Hammer
System will display first “Hit” data
If data is OK Press “Y” to save it to database, and add to stack
Press “N’ to discard data
Wait for Real Time Noise Monitor to show Low Noise
Hit Strike Plate with Hammer
System will display first “Hit” data
If data is OK Press “Y” to save it to database, and add to stack
Press “N’ to discard data
System will Display Stacked Data
Repeat Hit Sequence until Stacked data is OK
To Save Stacked data before total number of Hits entered in stack menu
Press “ESC” to Stop Acquisition
Press “F2” to “Save Stack” and “Clear Stack Counter”
After Saving Stack then Move to next Shot Point and repeat Hit Sequence