MX-2300/2700 N/G SIMULATION 7 – 38
<Setting range and default value of each value>
27-5
Purpose : Setting
Function (Purpose) : Used to set the tag number.
Section : Communication (RIC/MODEM)
Item : Data (User data)
Operation/Procedure
1) When the machine enters Simulation 27-05, the following
screen is displayed.
2) Enter the set value with 10-key. (Max. 8 digits)
The entered value is displayed on "NEW."
* Press [C] key to clear the entered value.
3) When [SET] button is pressed, the entered value is set.
When the entered value is set, it is displayed in "PRESENT:"
and "NEW" disappears.
27-6
Purpose :Setting
Function (Purpose) : Used to set YES/NO of the manual service
call.
Section : Communication (RIC/MODEM)
Item : Specifications
Operation/Procedure
1) Enter the set value with 10-key.
* Press [C] key to clear the entered value.
2) When [OK] button is pressed, the current set value is saved to
EEPROM and RAM.
* When [COLOR], or [BLACK] key is pressed, the current set
value is saved to EEPROM and RAM.
<Setting range and default value of each value>
Item Display Content
Setting
range
Default value Remark
A FSS MODE NEB1 FSS mode setting Only send in NE-B mode 0 1
NEB2 Send/Receive in NE-B mode 1
B RETRY Retry number setting 0 to 15 2 * 0: No retry
C TIMER (MINUTE) Retry timer setting (minute) 1 to 15 3
D TONER ORDER
TIMING (K)
100% – 75% Toner order auto send
timing setting (K)
100% to 75% 5 3 (49% to 25%)
74% – 50% 74% to 50% 4
49% – 25% 49% to 25% 3
LOWER 25 25% or less 2
NEAREND Near end 1
EMPTY Empty 0
E TONER ORDER
TIMING (C)
100% – 75% Toner order auto send
timing setting (C)
100% to 75% 5 3 (49% to 25%)
74% – 50% 74% to 50% 4
49% – 25% 49% to 25% 3
LOWER 25 25% or less 2
NEAREND Near end 1
EMPTY Empty 0
F TONER ORDER
TIMING(M)
100% – 75% Toner order auto send
timing setting (M)
100 to 75% 5 3 (49% to 25%)
74% – 50% 74% to 50% 4
49% – 25% 49% to 25% 3
LOWER 25 25% or less 2
NEAREND Near end 1
EMPTY Empty 0
G TONER ORDER
TIMING(Y)
100% – 75% Toner order auto send
timing setting (Y)
100% to 75% 5 3 (49% to 25%)
74% – 50% 74% to 50% 4
49% – 25% 49% to 25% 3
LOWER 25 25% or less 2
NEAREND Near end 1
EMPTY Empty 0
0
A:
A: 1
; FSS MODE: NEB2
B
: 2 ; RETRY
SIMULATION NO.27-04
FSS FUNCTION SETUP
1
[0~ 1]
OK
TEST
CLOSE
C : 3 ; TIMER (MINUTE)
D
: 3 ; TONER ORDER TIMING (K): 3 (49% - 25%)
SIMULATION NO.27-05
TEST
TAG# SETTING
0
11111111
PRESENT :
NEW :
SET
CLOSE
Item Display Content
Setting
range
Default
value
A (0:YES 1:NO) 0 Manual service call YES 0 to 1 0
1 Manual service call NO
:
A㧦 0
㧧 0:YES, 1:NO
SIMULATION
NO.27-06
MANUAL SERVICE CALL S ETUP
0
㨇 0㨪 1 㨉
OK
TEST