EasyManua.ls Logo

Sharp MX-2300 G - Page 151

Sharp MX-2300 G
428 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MX-2300/2700 N/G SIMULATION 7 – 45
43
43-1
Purpose : Setting
Function (Purpose) : Used to set the fusing temperature in each
operation mode.
Section :Fusing
Item : Operation
Operation/Procedure
1) Select the set item with [] and [] buttons.
The highlighted set value is switched and the value is dis-
played in the setting area.
* If there is any item over [], an active display is made and
item is shifted.
If there is no item over [], the display grays out and the
operation is invalid.
If there is any item under [], an active display is made and
item is shifted.
If there is no item over [], the display grays out and the
operation is invalid.
2) Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3) When [OK] button is pressed, the currently entered data are
saved to EEPROM and RAM.
* When [], [] button, [COLOR], or [BLACK] key is pressed,
the current set values is saved in EEPROM and RAM.
<Fusing temperature setting range and default values>
*1: Japan, China, AB_B
*2: U.S.A, Canada, Europe, U.K, Australia, Inch, AB_A
43-4
Purpose :Setting
Function (Purpose) : Used to set the fusing temperature in each
operation mode. (Continued from 43-01.)
Section :Fusing
Item : Operation
Operation/Procedure
1) Select the set item with [] and [] buttons.
The highlighted set value is switched and the value is dis-
played in the setting area.
* If there is any item over [], an active display is made and
item is shifted.
If there is no item over [], the display grays out and the
operation is invalid.
If there is any item under [], an active display is made and
item is shifted.
If there is no item over [], the display grays out and the
operation is invalid.
2) Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3) When [OK] button is pressed, the currently entered data are
saved to EEPROM and RAM.
When setting is completed, [OK] button returns to the normal
display.
* When [], [], [COLOR], or [BLACK] key is pressed, the current
set value is saved to EEPROM and RAM.
Item Display Content
Set
range
Default value
Group
A *1
Group
B *2
A HL_UM READY TH_UM set value in
READY standby
70 to
230
175 180
B HL_LM READY TH_LM set value in
READY standby
30 to
200
105 105
C HL_US READY TH_US set value in
READY standby
70 to
230
155 160
D HL_UM PLAIN
PAPER BW
BW normal paper
TH_UM set value
70 to
230
170 175
E HL_LM PLAIN
PAPER BW
BW normal paper
TH_LM set value
30 to
200
130 130
F HL_US PLAIN
PAPER BW
BW normal paper
TH_US set value
70 to
230
180 180
G HL_UM PLAIN
PAPER CL
COLOR normal
paper TH_UM set
value
70 to
230
170 175
H HL_LM PLAIN
PAPER CL
COLOR normal
paper TH_LM set
value
30 to
200
130 130
I HL_US PLAIN
PAPER CL
COLOR normal
paper TH_US set
value
70 to
230
180 180
J WARMUP
FUMON
HL_UM T
Fusing paper front
rotation start
TH_UM set value
30 to
200
145 145
K WARMUP
FUMOFF
HL_LM T
Fusing paper front
rotation start
TH_LM set value
30 to
200
75 75
LWARM UP
END TIME
WARM UP
complete time
30 to
255
76 76
M HL_UM HEAVY
PAPER
Heavy paper
TH_UM set value
70 to
230
170 170
N HL_LM HEAVY
PAPER
Heavy paper
TH_LM set value
30 to
200
140 140
O HL_US HEAVY
PAPER
Heavy paper
TH_US set value
70 to
230
175 175
PHL_UM OHP
PAPER
OHP-TH_UM set
value
70 to
230
170 170
Q HL_LM OHP
PAPER
OHP-TH_LM set
value
30 to
200
145 145
R HL_US OHP
PAPER
OHP-TH_US set
value
70 to
230
170 170
S HL_UM ENV
PAPER
Envelope TH_UM
set value
70 to
230
180 180
T HL_LM ENV
PAPER
Envelope TH_LM
set value
30 to
200
145 145
UHL_US ENV
PAPER
Envelope TH_US
set value
70 to
230
180 180
VHL_UM E-
STAR
TH_UM set value
when preheating
30 to
200
145 142
W TH_US E-
STAR
TH_US set value
when preheating
30 to
200
130 130
X PRE-JOB TH_UM set value
when resetting from
preheating
30 to
200
160 160
TH_UM Fusing upper thermister main
TH_LM Fusing lower thermister main
TH_US Fusing upper thermister sub
HL_UM Heater lamp upper main
HL_LM Heater lamp lower main
HL_US Heater lamp upper sub
Item Display Content
Set
range
Default value
Group
A *1
Group
B *2
0
A
:
A180
B105
C160
D175
㧧 HL_UM READY
㧧 HL_LM READY
㧧 HL_US READY
㧧 HL_UM PLAIN PA PER BW
SIMULATION
NO.43
01
FUSER TEMP SETUP FOR PAPER
180
70230
OK
TEST
CLOSE

Table of Contents

Other manuals for Sharp MX-2300 G

Related product manuals