MX-2300/2700 N/G SIMULATION 7 – 47
<Code descriptions in the above list>
43-21
Purpose : Setting
Function (Purpose) : Used to perform correction of high temper-
ature and high humidity (H/H) environment
for the fusing temperature setting 1 (SIM
43-01) for each paper.
Section :Fusing
Item : Operation
Operation/Procedure
1) When the machine enters SIM 43-21, the following screen is
displayed. (The current set value is displayed.)
2) Select the set item with [↑] and [↓] buttons.
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [↑], an active display is made and
item is shifted.
If there is no item over [↑], the display grays out and the
operation is invalid.
If there is any item under [↓], an active display is made and
item is shifted.
If there is no item over [↓], the display grays out and the
operation is invalid.
3) Enter the set value with 10-key.
* Press [C] key to clear the entered values.
4) When [OK] button is pressed, the currently entered data are
saved to EEPROM and RAM.
* When [↑], [↓], [COLOR], or [BLACK] key is pressed, the current
set value is saved to EEPROM and RAM.
* Input value: The intercept for the correction value is 50. This is
because the set value is kept as a positive number in case of a
negative setting due to negative correction.
• Set value: Value to be set (–49 to +49), Input value: Actual input
(1 to 99)
<List of setting parameters>
O HL_US HEAVY
LL
Correction value for heavy
paper TH_US set value
under LL environment
1 to 99 60
P HL_UMOHP LL Correction value for OHP
TH_UM set value under LL
environment
1 to 99 60
Q HL_LM OHP LL Correction value for OHP
TH_LM set value under LL
environment
1 to 99 60
R HL_US OHP LL Correction value for OHP
TH_US set value under LL
environment
1 to 99 60
S HL_UM
ENVELOPE LL
Correction value for
ENVELOPE TH_UM set
value under LL
environment
1 to 99 60
T HL_LM
ENVELOPE LL
Correction value for
ENVELOPE TH_LM set
value under LL
environment
1 to 99 60
U HL_US
ENVELOPE LL
Correction value for
ENVELOPE TH_US set
value under LL
environment
1 to 99 60
V HL_UM E-STAR
LL
Correction value for
preheating TH_UM set
value under LL
environment
1 to 99 60
W HL_US E-STAR
LL
Correction value for
preheating TH_US set
value under LL
environment
1 to 99 60
X PRE-JOB LL Correction value for
TH_UM set value when
resetting from preheating
under LL environment
1 to 99 60
TH_UM Fusing upper thermister main
TH_LM Fusing lower thermister main
TH_US Fusing upper thermister sub
HL_UM Heater lamp upper main
HL_LM Heater lamp lower main
HL_US Heater lamp upper sub
Item Display item Item content
Set
range
Default
value
OK
0
:
A:55
;
HL_UM
READY LL
SIMULATION
NO.43-20
FUSER
TEMP
ADJUSTMENT
(LL)
55
㨇1㨪99㨉
TEST
B:55
;
HL_LM
READY LL
C:55
;
HL_US
READY LL
D:55
;
HL_UM
PLAIN BW LL
CLOSE
Set value –49 –25 –5 0 +5 +25 +49
Input value 1 25 45 50 55 75 99
Item Item display Content of item
Set
range
Default
value
A HL_UM READY
HH
Correction value for
TH_UM set value in
READY standby under
HH environment
1 to 99 45
B HL_LM READY
HH
Correction value for
TH_LM set value in
READY standby under
HH environment
1 to 99 45
C HL_US READY
HH
Correction value for
TH_US set value in
READY standby under
HH environment
1 to 99 45
D HL_UM PLAIN
BW HH
Correction value for BW
plain paper TH_UM set
value under HH
environment
1 to 99 45
E HL_LM PLAIN
BW HH
Correction value for BW
plain paper TH_LM set
value under HH
environment
1 to 99 45
F HL_US PLAIN
BW HH
Correction value for BW
plain paper TH_US set
value under HH
environment
1 to 99 45
G HL_UM PLAIN
CL HH
Correction value for
COLOR plain paper
TH_UM set value under
HH environment
1 to 99 45
H HL_LM PLAIN
CL HH
Correction value for
COLOR plain paper
TH_LM set value under
HH environment
1 to 99 45
I HL_US PLAIN
CL HH
Correction value for
COLOR plain paper
TH_US set value under
HH environment
1 to 99 45
J WARMUP
FUMON HL_UM
T HH
Correction value for
fusing motor front rotation
start TH_UM set value
under HH environment
1 to 99 50
K WARMUP
FUMOFF HL_LM
T HH
Correction value for
fusing motor front rotation
end TH_UM set value
under HH environment
1 to 99 50