MX-2300/2700 N/G SIMULATION 7 – 50
43-24
Purpose : Setting
Function (Purpose) : Used to enter the correction values for SIM
43-1 and SIM 43-4 temperature correc-
tions.
Section :Fusing
Item : Operation
Operation/Procedure
1) Select the set item with [] and [] buttons.
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [], an active display is made and
item is shifted.
If there is no item over [], the display grays out and the
operation is invalid.
If there is any item under [], an active display is made and
item is shifted.
If there is no item over [], the display grays out and the
operation is invalid.
2) Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3) When [OK], [], [] button, [COLOR], or [BLACK] key is
pressed, the entered value is set.
* Input value: The intercept for the correction value is 50. This is
because the set value is kept as a positive number in case of a
negative setting due to negative correction.
Set value: Value to be set (–49 to +49)
Input value: Actual input value (1 to 99)
<Set range and default value of each setup>
* On adjustment values
Each temperature correction value Temperature 1°C change
by 1 count
Each paper exit count 1 sheet by 1 count
Each cool-down time 1s change by 1 count
<Code descriptions of the above list>
Set value –49 –25 –5 0 +5 +25 +49
Input value 1 25 45 50 55 75 99
Item Display items Item descriptions
Set
range
Default
value
A NN_120_ WUP_HL_UM & HL_US WARMUP end temperature
correction value
120°C or below when turning
on the power under NN
environment
Common to items
HL_UM, HL_US
1 to 99 50
B NN_120_WUP_HL_LM Item HL_LM 1 to 99 50
C LL_120_WUP_HL_UM & HL_US 120°C or below when turning
on the power under LL
environment
Common to items
HL_UM, HL_US
1 to 99 50
D LL_120_WUP_HL_LM Item HL_LM 1 to 99 50
E HH_120_WUP_HL_UM & HL_US 120°C or below when turning
on the power under HH
environment
Common to items
HL_UM, HL_US
1 to 99 50
F HH_120_WUP_HL_LM Item HL_LM 1 to 99 50
G ON_120_WUP_HL_UM Temperature correction value
immediately after completion of
warm-up and during continuation
of temperature correction
120°C or below when turning
on the power
Item HL_UM 1 to 99 40
H ON 120 WUP HL_US Item HL_US 1 to 99 55
I NN_120_ FUS_DUP_HL_UM & HL_US Fusing temperature correction
value
120°C or below when turning
on the power under NN
environment
Common to items
HL_UM, HL_US
1 to 99 55
J NN_120_ FUS_DUP_HL_LM Item HL_LM 1 to 99 50
K LL_120_ FUS_DUP_HL_UM & HL_US 120°C or below when turning
on the power under LL
environment
Common to items
HL_UM, HL_US
1 to 99 60
L LL_120_ FUS_DUP_HL_LM Item HL_LM 1 to 99 50
M HH_120_ FUS_DUP_HL_UM & HL_US 120°C or below when turning
on the power under HH
environment
Common to items
HL_UM, HL_US
1 to 99 50
N HH_120_ FUS_DUP_HL_LM Item HL_LM 1 to 99 50
O NN_120_ FUS_DUP_CNT Fusing duplex paper exit count Under NN environment 1 to 60 5
P LL_120_ FUS_DUP_CNT Under LL environment 1 to 60 10
Q HH_120_ FUS_DUP_CNT Under HH environment 1 to 60 5
R COOL_DOWN_HEAVY Cool-down time Heavy paper 1 to 60 15
S COOL_DOWN_OHP OHP 1 to 60 30
T COOL_DOWN_DEVELOP Envelope 1 to 60 40
U WUP DUP TIME Temperature correction
continuation time immediately
after completion of warm-up
-0 to 25590
TH_UM Fusing upper thermister MAIN center
TH_LM Fusing lower thermister MAIN
TH_US Fusing upper thermister SUB edge
HL_UM Heater lamp upper MAIN
HL_LM Heater lamp lower MAIN
HL_US Heater lamp upper SUB
0
A
:
A:50
B:50
C:50
D: 50
NN_120_WUP_HL_UM&HL_US
NN_120_WUP_HL_LM
LL_120_WUP_HL_UMHL_US
LL_120_WUP_HL_LM
SIMULATION NO.43-24
FUSER TEMP RESET
50
1 99
OK
TEST
CLOSE