MX-2300/2700 N/G SIMULATION 7 – 49
* PLAIN BW DUPCNT LL, PLAIN CL DUPCNT LL, HEAVY BW
DUP APCNT LL, HEAVY CL DUP APCNT LL 1s change by 1
count
The other correction values 1°C change by 1 count
<Code descriptions in the above list>
43-23
Purpose : Setting
Function (Purpose) : Used to perform H/H (high temperature,
high humidity) correction for the fusing tem-
perature setting 1 (SIM 43-04) for each
paper.
Section :Fusing
Item : Operation
Operation/Procedure
1) When the machine enters Simulation 43-23, the following
screen is displayed. (The current set value is displayed.)
2) Select the set item with [] and [] buttons.
The highlighted set value is switched and the value is dis-
played in the setting area.
* If there is any item over [], an active display is made and
item is shifted.
If there is no item over [], the display grays out and the
operation is invalid.
If there is any item under [], an active display is made and
item is shifted.
If there is no item over [], the display grays out and the
operation is invalid.
3) Enter the set value with 10-key.
* Press [C] key to clear the entered values.
4) When [OK], [], [] button, [COLOR], or [BLACK] key is
pressed, the currently entered data are saved to EEPROM and
RAM.
* Input value: The intercept for the correction value is 50. This is
because the set value is kept as a positive number in case of a
negative setting due to negative correction.
Set value: Value to be set (–49 to +49)
Input value: Actual input value (1 to 99)
<List of setting parameters>
* PLAIN BW DUPCNT HH, PLAIN CL DUPCNT HH, HEABY BW
DUP APCNT HH, HEABY CL DUP APCNT HH 1s change by
1 count
The other correction values 1°C change by 1 count
<Code descriptions in the above list>
H PLAIN CL DUP
APP CNT LL
Correction value for
COLOR plain paper
duplex applicable number
of sheets under LL
environment
1 to 99 50
TH_UM Fusing upper thermister main
TH_LM Fusing lower thermister main
TH_US Fusing upper thermister sub
HL_UM Heater lamp upper main
HL_LM Heater lamp lower main
HL_US Heater lamp upper sub
Set value –49 –25 –5 0 +5 +25 +49
Input value 1 25 45 50 55 75 99
Item Display item Item content
Set
range
Default
value
0
A
:
A:60
㧧
HL_UM PLAI N BW DUP
FUSSIMULATION NO.43-22
60
1㨪 99
TEST
B:60
㧧
HL_LM PLAIN BW DUP
C:60
㧧
HL_US PLAIN BW DUP
D:50
PLAIN BW DUP APP CNT LL
CLOSE
OK
Item Display item Item content
Set
range
Default
value
A HL_UM PLAIN BW
DUP HH
Correction value for
TH_UM BW plain paper
duplex under HH
environment
1 to 99 45
B HL_LM PLAIN BW
DUP HH
Correction value for
TH_LM BW plain paper
duplex under HH
environment
1 to 99 50
C HL_US PLAIN BW
DUP HH
Correction value for
TH_US BW plain paper
duplex under HH
environment
1 to 99 45
D PLAIN BW DUP
APP CNT HH
Correction value for
BW plain paper duplex
applicable number of
sheets under HH
environment
1 to 99 50
E HL_UM PLAIN CL
DUP HH
Correction value for
TH_UM COLOR plain
paper duplex under HH
environment
1 to 99 45
F HL_LM PLAIN CL
DUP HH
Correction value for
TH_LM COLOR plain
paper duplex under HH
environment
1 to 99 50
G HL_US PLAIN CL
DUP HH
Correction value for
TH_US COLOR plain
paper duplex under HH
environment
1 to 99 45
H PLAIN CL DUP APP
CNT HH
Correction value for
COLOR plain paper
duplex applicable
number of sheets under
HH environment
1 to 99 50
TH_UM Fusing upper thermister main
TH_LM Fusing lower thermister main
TH_US Fusing upper thermister sub
HL_UM Heater lamp upper main
HL_LM Heater lamp lower main
HL_US Heater lamp upper sub
OK
0
A
:
A:45
HL_UM PLAIN BW DUP HH
SIMULATION
NO.43-23
FUSER TEMP ADJUSTMENT (HH:DUP)
45
1㨪99
TEST
B:50
HL_LM PLAIN BW DUP HH
C:45
HL_US PLAIN BW DUP HH
D:50
PLAIN BW DUP APP CNT HH
CLOSE