MX-2300/2700 N/G SIMULATION 7 ā 54
[OTHER] button: Display of environment area, membrane
decrease correction steps and process control execution
counter, and model type.
* When [CLOSE] button is pressed, the display shifts to the copy
basic screen of simulation.
* Copying can be performed also by pressing [COLOR]/[BLACK]
key.
<Display item and content description>
Mode Page number Display item (*: correction value) Content description Display range
Default
value
CPY/PRN 1/2 P (PROCON) Left BLACK : GB ***/*** DV ***/*** High density process control GB/DV
data (KCMY)
GB: 230 to 850
DV: 0 to 700
GB: 630
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
N (M)
(NORMAL
(MIDDLE))
Right BLACK : GB ***/*** DV ***/*** High density normal (middle speed
display) GB/DV data (KCMY)
GB: 230 to 850
DV: 0 to 700
GB: 630
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
2/2 N (L) (NORMAL
(LOW))
BLACK : GB ***/*** DV ***/*** High density normal (low speed
display) GB/DV data (KCMY)
GB: 230 to 850
DV: 0 to 700
GB: 600
DV: 400
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
OTHER 1/10 TN/TC Left TN HUD AREA Toner control display humidity area 1 to 14 9
TN HUD DATA Toner control display humidity AD
value
0 to 1023 0
TC TMP AREA Transfer display temperature area 1 to 9 4
TC TMP DATA Transfer display temperature AD value 0 to 1023 0
Right TC HUD AREA Transfer display humidity area 1 to 9 4
TC HUD DATA Transfer display humidity AD value 0 to 1023 0
MD HUD AREA Membrane decrease display humidity
area
1 to 14 9
MD HUD DATA membrane decrease display humidity
AD value
0 to 1023 0
2/10 DRUM Left MD K STEP Drum membrane decrease correction
step display (KCMY)
0 to 4 0
MD C STEP
MD M STEP
MD Y STEP
MD K DRUM COUNTER Membrane decrease drum traveling
distance area
0 to 20 0
MD C DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
3/10 VG MD K REVISE(VG) : L *** M *** H*** Drum membrane decrease grid voltage
correction display (KCMY)
0 to 255 0
MD C REVISE(VG) : L *** M ***
MD M REVISE(VG) : L *** M ***
MD Y REVISE(VG) : L *** M ***
4/10 LD MD K REVISE(LD) : L *** M *** H*** Drum membrane decrease laser power
voltage correction (KCMY)
0 to 255 0
MD C REVISE(LD) : L *** M ***
MD M REVISE(LD) : L *** M ***
MD Y REVISE(LD) : L *** M ***
5/10 HV MD K REVISE(HV) : L *** M *** H*** High density membrane decrease
environment GB correction display
(KCMY)
0 to 255 0
MD C REVISE(HV) : L *** M ***
MD M REVISE(HV) : L *** M ***
MD Y REVISE(HV) : L *** M ***
6/10 CP MD K REVISE(CP) : L *** M *** H*** Drum membrane decrease
environment grid voltage correction
display (KCMY)
0 to 255 0
MD C REVISE(CP) : L *** M ***
MD M REVISE(CP) : L *** M ***
MD Y REVISE(CP) : L *** M ***
7/10 DL MD K REVISE COL (DL): L *** M *** Drum membrane decrease discharge
light quantity correction (%)
0 to 100 50
MD C REVISE COL (DL): L *** M ***
MD M REVISE COL (DL): L *** M ***
MD Y REVISE COL (DL): L *** M ***
8/10 DL EV MD K REVISE COL (DL EV): L *** M*** Drum membrane decrease
environment discharge light quantity
correction (%)
ā100 to 100 0
MD C REVISE COL (DL EV): L *** M***
MD M REVISE COL (DL EV): L *** M***
MD Y REVISE COL (DL EV): L *** M***