Mounting
28 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
6.4 Placement of multiple distance measuring device
Multiple distance measuring device If you want to mount several distance measuring devices, you have to
consider a minimum distance between the distance measuring devices
when mounting them. The minimum distance increases with the maximum
scanning range of the distance measuring device.
Formula a≥100mm+0.01xs
max
[mm]
Example Distance measuring device DL100–21xxxx01
Measuring range: 0.15 … 100 m
Maximum measuring distance 60 m
s
max
= 60 m
Calculation
a≥100mm+0.01x60000mm100mm+600mm 700 mm
Result
a≥700mm
Light beams in the same direction
s
m
a
x
.
a
S
et
E
s
c
<
<
S
et
E
s
c
<
<
Fig. 9: Placement of two distance measuring devices with light beams in the
same light direction.
1 Distance measuring device DL100 Pro
2 Reector
a Minimum distance
s
max
Maximum scanning range