Operation at the measuring device
44 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
8.5.4 Menu"Pron"
Youcangettothemenu"Pron"viathemenupath:
Main menu → → Menu → →Pron
Push the
-key so that the parameter "StName" is displayed.
Use the keys
and to browse within the menu. Push the -key to
display the respective parameter value.
Parameter Description
StName Display station name
Factory setting
• dl100
ResDst Choose resolution for the output value "Distance" via the digi-
tal data interface. The measurement value is multiplied with
theresolution.Theparameterdoesnotinuencethemeasure-
ment value displayed.
Prerequisite
The parameter is only displayed if the option "Yes" is selected
for the parameter "more".
Options
• 0.1
• 0.125
• 1.0
• 10.0
• 100.0
• freRes
Factory setting
• 0.1 mm
Menu"Pron"
(continued)
Options Description
ResSpd Choose resolution for the output value "Speed" via the
digital data interface. The measurement value is multiplied
withtheresolution.Theparameterdoesnotinuencethe
measurement value displayed.
Prerequisite
• The parameter is only displayed if the option "Yes" is
selected for the parameter "more".
Options
• 0.1
• 1.0
• 10.0
• 100.0
• freRes
Factory setting
• 0.1 mm/s
Table 12: Menu "Pron"