8.5.8 Submenu "MF1 – Dist"
This submenu is used to parameterize the multifunction output MF1 as
distance switching output.
You can get to the menu "Dist" via the menu path:
Main menu
Menu Pron more
MFx On MF1 Actsta Functn Dist
Requirements for the display
Menu "more": Option "Yes"
Menu "MFx On": Option "Enable"
Parameter "Functn": Option "Dist"
Parameter Description
Limit Set distance-dependent switching threshold
Hysteresis Set Hysteresis for the switching threshold
Table 16: Submenu "MF1 – Dist"
inactiv
e
active
Limit
Hyst
Dist
.
Fig. 24: Displaying the function "Dist."
Limit Distance-dependent switching threshold
Hyst: Switching threshold hysteresis
Dist: Measured distance