Operation via Ethernet (Ethernet interface)
68 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
9.2.6 Ethernet settings
Field Description
Static Ethernet
settings
• MAC address display. Example 00:06:77:27:37:0E
Dynamic Ether-
net settings
• TCP/IP address: IP address display and manual input in
cases where an IP address is assigned non-dynamically.
Default: 192.168.100.236
• Network mask: Display and input of subnet mask. Default:
255.255.255.0
• Gateway: Display and input of gateway address. Default:
0.0.0.0
Save dynamic
Ethernet set-
tings
• Save settings
PROFINET con-
guration
• PROFINET station name.
• Manual input. Default: dl100hf
Table 48: Seite „Ethernet-Einstellungen“
9.2.7 Methods
Field Description
Device reboot • Click the button "Reboot" to cause the device to restart.
Read/Write access
• Write only
Laser control Switchthelaseronandoasfollows:
• Use the selection button to select the desired option.
• Click the button to perform the option.
Read/Write access
• Write only
Input value
• 0:o/1:on
Factory setting
• O
Heating control Control the heating as follows:
• Use the selection button to select the desired option.
• Click the button to perform the option.
Read/Write access
• Write only
Input value
• 0:O/1:On/2:Auto
Factory setting
• Auto
Table 49: Page "Methods"