PROFINET IO-interface
82 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
Output values
(continued)
Rel. Adr. Description
0.31 Bit 31 is not set (0):
The value in the Bits 0 … 29 is assumed as new preset
valuebuttheosetisnotre-calculated.Thedistancevalue
outputisnotinuenced.
Bit 31 is set (1):
The value in the bits 0…29 is assumed as new present
value. Additionally, the preset function is called. This
functioncalculatesanewosetsothatthecurrentdistance
is now also output as the distance with the newly calculated
osetvalue.Allparametersarewrittenintheashmemory.
When Bit 30 is set, the Bit 31 is ignored.
Type
Bit: 0 or 1
Module parameter
Name Description
Resolution Determines the distance value resolution; 1 digit may
correspond to 0.1 mm, 0.125 mm, 1 mm, 10 mm or 100 mm.
Value range
0.1 mm
0.125 mm
1 mm
10 mm
100 mm
free Distance Resolution [µm]
Standard value
0.1 mm
Free distance
resolution
Determines the resolution of the distance value if the value
“free Distance Resolution [µm]” has been selected in the
“Resolution” parameter.
Value range
1 ... 100,000 µm
Default value
100 µm
10.3.6 Module 6: "Time/i4w, Distance/i2w"
Type Input module, 6 words, consistent
Description This module reads the current distance value according to the settings of
osetandresolution.Additionally,themodulereceivesthetimestampfor
the time at which the measurement value was recorded.
Notes Ifadeviceerror,missingreectororcontaminationledtonovalid
measurement value being present, the value "0" is output for distance and
the corresponding bits are set in the status bytes.