8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 53
Operation at the measuring device
8.5.13 Menu"Oset"
Setanosetviathismenu.
Youcangettothemenu"Oset"viathemenupath:
Main menu
Menu Prob more
MFx On (MF1 MF2 →)Oset
Push the
key.Thecurrentlysetosetisdisplayedhere.
Requirements for the display
Menu "more": Option "Yes"
Value Description
Oset Specifyoset.Theosetisaddedtotheinternallydetermined
measurementvalue.Theosetaectsalloutputsandthe
display indication.
Whenthe"Preset"functionisactivated,theosetisover-
written by triggering of the preset input.
Adjustment range
–600000…+300000mm
Factory setting
0 [mm]
Table 21: M
enu "Oset"
8.5.14 Menu “SpecFu”
Set special functions via this menu.
You can get to the menu “SpecFu” via the menu path:
Main menu
Menu Pron more
MFx On (MF1 MF2 →)Oset SpecFu
Push the
key so that the parameter “AvgDst” is displayed.
Use the keys
and to browse within the menu.
Requirements for the display
Menu “more”: Option “Yes”
Parameter Description
AvgDst Selectlterdepthforthedistancevalues.
Options
Medium
Slow
Fast
Factory setting
Medium