Operation via Ethernet (Ethernet interface)
56 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
9 Operation via Ethernet (Ethernet interface)
The distance measuring device DL100 Pro is equipped with two Ethernet
interfaces. They serve communication via PROFINET IO and diagnosis and
parameterization via SOPAS ET. The two interfaces have equal priorities
and are internally connected to one switch.
NOTE!
The conguration program SOPAS ET can be downloaded
from "www.sick.com".
NOTE!
Parameters congured by Ethernet (SOPAS ET) are over-
written with the PROFINET IO parameters once the device
is integrated into a PROFINET network.
9.1 IP-networkconguration
IP-networkconguration–
deliveryconguration
The distance measuring device is delivered with the following IP-network
conguration:
• IP address: 192.168.100.236
• IP network mask: 255.255.255.0
• Standard gateway: 0.0.0.0
InvalidIPnetworkconguration IfthesystemdetectsaninvalidIPnetworkcongurationthenthedelivery-
statecongurationisusedinstead.
9.2 Ethernet parameter list
9.2.1 Device information
Field "Device information"
Parameter Description
Device type Display of the device type
Read/Write access
• Read only
Serial number Display of the device's serial number
Read/Write access
• Read only
Table 23: Page "Device information" – eld "Device information"