Operation at the measuring device
48 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
8.5.9 Submenu "MF1 – Speed"
This submenu is used to parameterize the multifunction output MF1 as
speed output.
You can get to the menu "Speed" via the menu path:
Main menu
Menu Pron more
MFx On MF1 Actsta Functn Speed
Requirements for the display
Menu "more": Option "Yes”
Menu "MFx On": Option "Enable"
Parameter "Functn": Option "Speed"
Parameter Description
Limit Set speed for the switching threshold The switching output is
activated when the current speed exceeds the set speed. The
switchinghysteresisissetrmlyto±0.1m/s.
Adjustment range
Range 0.0 … 9.9 m/s
Factory setting
0 [mm]
Sign Choose the travel direction to be monitored.
Options
+/–:Oncethesetspeedisexceededinonedirection,the
switching output is activated.
+:Oncethesetspeedisexceededwithincreasingdistance,
the switching output is activated.
–: Once the set speed is exceeded with decreasing distance,
the switching output is activated.
Factory setting
+/–
Table 17: Submenu "MF1 – Speed"