8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 87
PROFINET IO-interface
Input values
(continued)
Rel. Adr. Description
1.3 Bit = 1: MF2 is active.
Type
1 bit
1.4 ... 1.6 Reserved
Type
1 bit
1.7 Bit = 1: No distance or speed measurement value can be
read.
Bit = 0: Current measurement value is valid.
Type
1 bit
Output values
Rel. Adr. Description
0.1 ... 0.7 Reserved
Type
1 bit
1.0 Bit = 1: Deactivate laser
Bit = 0: Activate laser
Type
1 bit
1.1 ... 1.7 Reserved
Type
1 bit
10.3.9 Module 13: "13-Temp/i1b, Level/i2b, Hrs/i2b"
Type Input module, 5 bytes , consistent
Description In this module, diagnosis data can be read from the device.