8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 85
PROFINET IO-interface
Module parameter
Name Description
Distance
resolution
Determines the distance value resolution; 1 digit may
correspond to 0.1 mm, 0.125 mm, 1 mm, 10 mm or 100 mm.
Value range
• 0.1 mm
• 0.125 mm
• 1 mm
• 10 mm
• 100 mm
• free Distance Resolution [µm]
Standard value
• 0.1 mm
Free distance
resolution
Determines the resolution of the distance value if the value
“free Distance Resolution [µm]” has been selected in the
“Resolution” parameter.
Value range
• 1 ... 100,000 µm
Default value
• 100 µm
Speed
resolution
Determines the speed value resolution; 1 digit may correspond
to 0.1 mm/s, 1 mm/s, 10 mm/s or 100 mm/s.
Value range
• 0.1 mm/s
• 1 mm/s
• 10 mm/s
• 100 mm/s
• free Speed Resolution [µm/s]
Standard value
• 1 mm/s
Free speed
resolution
Determines the resolution of the speed value if the value “free
Speed Resolution [µm/s]” has been selected in the “Resolu-
tion” parameter.
Value range
• 1 ... 100,000 µm/s
Default value
• 1,000 µm/s
10.3.8 Module 10: "Status/i2b, Control/o2b"
Type Input and output module, 2 bytes
Description This module reads the status bytes of the device and writes the control
bytes into the device.