Operation at the measuring device
54 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
Menu “SpecFu”
(continued)
Parameter Description
AvgSpd Selectlterdepthforthespeedvalues.
Options
• Medium
• Slow
• Fast
Factory setting
• Medium
MsrDir Deningthemeasuringdirection:
Ifthemeasuringdirectionispositive“+”,thedistanceoutput
value is equal to the internal distance value measured by the
measuring module. If the measuring direction is negative “-”,
the internal distance value is multiplied by a factor of “-1”.
Thechangeindirectionaectsboththeoutputvalueforthe
distance and the output value for the speed.
Options
• +
• -
Factory setting
• +
ErrRej Select time for error suppression. During this time, the old
measurement value is output. When there still is no valid
measurement value after the time selected for the parameter
"ErrRej", the value "0" is output.
Options
• 200ms: Error/warning is indicted when the error is present
for longer than 200 ms.
• 50ms: Error/warning is indicted when the error is present
for longer than 50 ms.
• OError/warningisindicatedatonce,withoutdelay.
Factory setting
• 200ms
Heat Requirements for the display
• Only for versions with heating DL100-xxHxxxxx
This menu is used to set the temperature at which the heating
istoactivate.Thehysteresisissetrmlyto2K.
Adjustment range
• -10…+40°C
Factory setting
• -10 °C