Operation at the measuring device
54 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
Menu “SpecFu”
(continued)
Parameter Description
AvgSpd Selectlterdepthforthespeedvalues.
Options
Medium
Slow
Fast
Factory setting
Medium
MsrDir Deningthemeasuringdirection:
Ifthemeasuringdirectionispositive“+”,thedistanceoutput
value is equal to the internal distance value measured by the
measuring module. If the measuring direction is negative “-”,
the internal distance value is multiplied by a factor of “-1”.
Thechangeindirectionaectsboththeoutputvalueforthe
distance and the output value for the speed.
Options
+
-
Factory setting
+
ErrRej Select time for error suppression. During this time, the old
measurement value is output. When there still is no valid
measurement value after the time selected for the parameter
"ErrRej", the value "0" is output.
Options
200ms: Error/warning is indicted when the error is present
for longer than 200 ms.
50ms: Error/warning is indicted when the error is present
for longer than 50 ms.
OError/warningisindicatedatonce,withoutdelay.
Factory setting
200ms
Heat Requirements for the display
Only for versions with heating DL100-xxHxxxxx
This menu is used to set the temperature at which the heating
istoactivate.Thehysteresisissetrmlyto2K.
Adjustment range
-10…+40°C
Factory setting
-10 °C