8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 51
Operation at the measuring device
Submenu “MF1 – Preset”
Main menu
Menu Pron more
MFx On MF1 Actsta Functn Preset
Requirements for the display
Menu "More" Option "On"
Menu "MFx On": Option "Enable"
Parameter "Functn": Option "Preset"
Parameter Description
sPrset The preset serves as initialization value. When the
multifunction input MF1 is activated, the preset is used.
Adjustment range
–300000
+300000
Since the display only has six digits, you may only enter
negative values up to "–99999" in the display.
Factory setting
10
Table 19: Submenu "MF1 – Preset"
Set Preset 1. Select the function "Preset" for the multifunction input MF1
2. Enter the parameter "Preset" for the desired initialization value.
3. Move the vehicle to the initialization position.
4. Activate the multifunction input MF1, e.g. via a proximity initiator, photo-
electric sensor or switch.
5. The output value of the distance measuring device corresponds to the
value set for "Preset" at the initialization position.