PROFINET IO-interface
74 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
Module number Overallsize Module type Content
Code Type Size
7 8 words Input module Timestamp Input 4 words
Distance Input 2 words
Speed Input 2 words
Table 53: Module overview – “01_Measured values
Module category “02_Device state”
Module number Overallsize Module type Content
Code Type Size
10 2 bytes Input and
output modules
Status Input 16 bit
Control(LaserO) Output 16 bit
13 5 bytes Input module Temperature [°C] Input 1 byte
Signal level [dB] Input 2 bytes
Service hours [10h] Input 2 bytes
Table 54: Module overview – “02_Device state”