PROFINET IO-interface
94 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
Module parameter
Name Description
Average Filter
Distance
Selectlterstrengthforthedistancemeasurements.
Value range
AlmostThedistancevalueisoutputnearlyunltered
Medium:Shorterrormeasurementsareltered.
Slow error measurements are mainly smoothed.
Standard value
Medium:
Average Filter
Speed
Selectlterstrengthspeedmeasurementvalue.
Value range
AlmostThespeedvalueisoutputnearlyunltered
Medium:Shorterrormeasurementsareltered.
Slow error measurements are mainly smoothed.
Standard value
Medium:
Measuring
Direction
Select measuring direction for the distance.
Value range
Negative direction [-].
Positivedirection[+]
Default value
Positivedirection[+]
Error Rejection Determine time for error suppression. During this time, the old
measurement value is output. If there still is no valid measure-
ment after the set time, the value "0" is output.
Value range
O
50ms
200ms
Standard value
200ms
Heating
Threshold
[degC]
Switching threshold in degrees Celsius, under which the
heating is activated
Value range
–10 ... 40 °C
Standard value
-10 °C