PROFINET IO-interface
94 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
Module parameter
Name Description
Average Filter
Distance
Selectlterstrengthforthedistancemeasurements.
Value range
• AlmostThedistancevalueisoutputnearlyunltered
• Medium:Shorterrormeasurementsareltered.
• Slow error measurements are mainly smoothed.
Standard value
• Medium:
Average Filter
Speed
Selectlterstrengthspeedmeasurementvalue.
Value range
• AlmostThespeedvalueisoutputnearlyunltered
• Medium:Shorterrormeasurementsareltered.
• Slow error measurements are mainly smoothed.
Standard value
• Medium:
Measuring
Direction
Select measuring direction for the distance.
Value range
• Negative direction [-].
• Positivedirection[+]
Default value
• Positivedirection[+]
Error Rejection Determine time for error suppression. During this time, the old
measurement value is output. If there still is no valid measure-
ment after the set time, the value "0" is output.
Value range
• O
• 50ms
• 200ms
Standard value
• 200ms
Heating
Threshold
[degC]
Switching threshold in degrees Celsius, under which the
heating is activated
Value range
• –10 ... 40 °C
Standard value
• -10 °C