Approach
1
M5 threaded mounting hole at the bottom
Direct mounting using the threaded holes at the bottom of the device
b
Use all of t
he M5 threaded holes at the bottom of the device so the values given in
the data sheet for vibration and shock resistance are achieved.
b
Maximum depth of thread engagement: 7.5mm.
b
Tightening torque: 2.5Nm.
b
In case of strong vibrations, use screw locking devices to secure the fixing screws.
1
M5 threaded mounting hole at the side
Direct mounting using the threaded holes at the sides
b
Use all of the M5 threaded holes at the sides so the values given in the data sheet
for vibration and shock resistance are achieved.
b
Maximum depth of thread engagement: 5.5mm.
b
Tightening torque: 2.5Nm.
b
In case of strong vibrations, use screw locking devices to secure the fixing screws.
Complementary information
To facilitate mounting and alignment, SICK offers mounting kits as accessories.