13 Technical data
13.1 Data sheet
Features
T
able 42: Features
Scanning range see "Scanning range", page 95
Protective field range ≤2m
≤4m in Incr
eased scanning range mode
Warning field range ≤7.3m
ROI scanning range ≤4m
Distance measurement range ≤16m
1)
Fields ≤24
Simultaneously monitored fields ≤3
Field sets ≤24
ROIs ≤40
Simultaneously monitored ROIs ≤5
ROI sets ≤40
Generally necessary protective field
supplement (
TZ = tolerance zone of
the safety camera sensor)
65mm
ROI measurement accuracy 50mm
1)
For values >9m, quality losses (e.g. larger statistical measurement errors) must be expected.
Safety-related parameters
T
able 43: Safety-related parameters
Typ (IEC61496) Type 2
Safety integrity level (IEC61508) SIL1
Safety integrity level (IEC62061) SIL1
Category(ISO13849) Category 2
Performance level (ISO13849) PL c
PFH
D
(me
an probability of a danger‐
ous failure per hour)
8 × 10
-7
T
M
(mis
sion time) 20years
Interfaces
T
able 44: Interfaces
OSSD pairs 2 (configurable)
Voltage supply and I/O
Connection type Male connector, M12, 8-pin, A-coding (collective male
c
onnector for voltage supply and inputs and outputs)
Length of cable with 0.25mm²
w
ire cross-section
10m
Configuration and diagnostic interface
Type of interface Ethernet
1000Base-T, IEEE 802.3ab
Connection type Female connector, M12, 8-pin, X-coded