11.2.1 Data recorder
Overview
Figure 36: Data recorder
Y
ou can use the data recorder to record the device’s signals. Depending on the inter‐
face and the load on the interface, the measurement data may not be transmitted and
shown for every detection cycle.
The data is saved in a data recorder diagnostics file.
You can play the data recorder diagnostic file in the data recorder.
You can adjust the settings in the Safety Designer main window.
Table 39: Data recorder
Start recording
Stop recording
Important information
NOTE
R
ecording with the data recorder can produce several gigabytes of data per minute.
b
Ensure that sufficient storage space is available.
Prerequisites
•
Exis
ting connection between Safety Designer and device
•
Configuration in the project and configuration in the device are synchronized.
Typical applications
•
Chec
k spatial geometry
•
Check where a person can stay or when a person is detected
TROUBLESHOOTING 11
8025919/1I9E/2023-01-09 | SICK O P E R A T I N G I N S T R U C T I O N S | safeVisionary2
85