Input voltage LOW 0V (–30V … 5V)
Input current HIGH 2mA … 3mA
Input current LOW 0mA … 2mA
Input capacitance Typ. 10nF
Input frequency (max. switching
seq
uence when used as control
input)
≤20Hz
Sampling time 4ms
Response time at EDM after switch‐
ing on OSSDs (when used as EDM
input)
300ms
Actuating duration of control switch
f
or reset (when used as reset input)
60ms to 30s
Actuating duration of switch for
standby (when used as sleep mode
input)
≥120ms
1)
The power-up delay may be different at ambient temperatures <0°C.
2)
Voltages as measured directly at the device connection. The voltage drop across the cables must be
c
onsidered separately.
Mechanical data
T
able 46: Mechanical data
Dimensions (W × H × D) 70mm × 80mm × 77mm
Weight 520g
Housingmaterial Aluminum
Housing color RAL 9005 (black) and RAL 1021 (colza yellow)
Material of the front screens Polycarbonate
Ambient data
T
able 47: Ambient data
Enclosure rating IP65 and IP67 (IEC60529)
Ambient light immunity 3000lux (IEC61496-3), typical immunity 10klx
Ambient operating temperature –10°C … +50°C
A
t temperatures ≥40°C, it is necessary to use heat
sinks.
Storage temperature –25°C … +70°C
Air humidity ≤95%, non-condensing
1)
Operating altitude Max. 2,300m above sea level
Vibration resistance 5Hz … 200Hz/1g (IEC60068-2-6)
Shock resistance, single shock 15g, 11ms (IEC60068-2-27)
EMC According to IEC61496-1, IEC61000-6-2,
IE
C61000-6-4
1)
IEC61496-1, no. 4.3.1and no. 5.4.2, IEC61496-3, no. 4.3.1 and no. 5.4.2. Condensation has an
inf
luence on normal operation.
Miscellaneous data
T
able 48: Miscellaneous data
Type of light Pulsed laser
Wavelength 855nm
13 TECHNICAL DATA