Data content selection
D
ata content selection
°
Filtered measurement data
The measurement data is pre-filtered. Noise and measurement artifacts are
r
educed.
°
U
nfiltered measurement data
The unfiltered measurement data is output.
Reduced bandwidth: If ac
tive, the intensity values are omitted.
7.14 Transferring a configuration
Overview
A c
onfiguration is first saved in your Safety Designer project as a configuration file. You
transfer the configuration to the connected device.
At the left, you see the values configured in the project for the device. If the device is
connected, you see the values saved in the device at the right.
The compatibility of the configuration is checked during transmission. An existing con‐
figuration on the device is overwritten.
Approach
1.
Check the configuration carefully before transmission.
2. Click on Identify the device to ensure that the desired device is connected.
3. If the checksums on the computer and the device differ, click on Transfer to device.
SafetyDesigner displays the transfer process.
Complementary information
A checksum is used as a unique identification for a configuration. Using the checksum,
it is possible to work out whether a setup was changed or whether two devices have the
same configuration.
The checksum of the configuration in the project may not match the checksum in the
device, for example if a field geometry has been modified, but not yet transmitted to the
device.
7.15 Verify configuration
Overview
B
y verifying the configuration, you can confirm that the configuration complies with the
planned safety function and fulfills the requirements in the risk assessment.
During verification, Safety Designer reads back the configuration transferred to the
device. It compares the configuration with the configuration saved in Safety Designer. If
both configurations are identical, Safety Designer displays the verification report. If the
user confirms that this is correct, the system is considered to be verified.
Important information
DANGER
H
azard due to lack of effectiveness of the protective device
Errors can occur when transferring the configuration to the device, e.g., due to environ‐
mental influences or faulty cables. The verification report always contains exactly the
settings that are stored in the device.
b
Before confirming, check the verification report carefully.
7 CONFIGURATION