5 Mounting
5.1 Mounting the heat sink
Approach
Figure 27: Mounting the heat sink
b
Scr
ew the heat sink into the M5 threaded holes located at the side.
b
Maximum depth of engagement: 5.5mm.
b
Tightening torque: 2.5Nm.
b
In case of strong vibrations, use screw locking devices to secure the fixing screws.
Complementary information
If y
ou are using heat sinks, then only the threaded holes on the bottom of the device
are available for mounting.
Further topics
"Pr
otection from overheating", page 23
"Heat sink", page 100
"Dimensional drawings", page 97
5.2 Mounting the device
Overview
Y
ou can use either the threaded holes at the sides or the threaded holes at the bottom
of the device for direct mounting.
Prerequisites
Pr
oject planning is completed.
Assembly is carried out according to the project planning.
Dangerous condition of the machine is and remains switched off during mounting.
The outputs of the device do not affect the machine during mounting.
MOUNTING 5
8025919/1I9E/2023-01-09 | SICK O P E R A T I N G I N S T R U C T I O N S | safeVisionary2
51
Subject to change without notice