7.2.5 Configuring devices offline
Overview
If no de
vices are connected to the computer, select the devices from the device catalog.
You then configure the devices offline. Diagnostics functions are not available.
You can connect the computer to the devices later, assign devices to the device tiles,
and transfer the configuration to the devices.
Approach
1.
In the main window, open the main navigation Configuration.
2. Add a device tile.
Further topics
"A
dd device tile", page 58
7.2.6 User groups
Overview
T
he devices contain a hierarchy of user groups that regulate access to the devices.
For certain actions (e.g., transferring a configuration to the device), you are requested
to log onto the device with the respective user group.
Important information
NOTICE
W
hen you log into a device, the configuration software stores the password so that you
do not need to re-enter it for other configuration steps.
If you do not change any other settings in the login dialog, the password is deleted as
soon as you exit the configuration software, or log out in the main window or Device
window.
If you enable the Temporarily store password for login on additional devices. function, the
password will be retained even if you log out in the device window only.
If you leave the computer unattended, you must log off to prevent unwanted access to
the device.
User groups
T
able 23: User groups
User group Password Authorization
Operator No password required. Anyone can
lo
g on as a machine operator.
Ma
y read configuration from the
device.
Maintenance
per
sonnel
Deactivated ex-works, i.e. it is not
initially possible to log on as a
maintenance technician. The user
group can be activated by the user
group administrator and provided
with a password.
Ma
y read configuration from the
device.
May transmit verified configura‐
tion to the device.
Change own password allowed.
CONFIGURATION 7
8025919/1I9E/2023-01-09 | SICK O P E R A T I N G I N S T R U C T I O N S | safeVisionary2