Error
Indic
ates an error.
•
Device error setting: Device faults are serious errors where all safety outputs switch
to the OFF state and the device changes to the interlocked state. Once the cause
of the error has been rectified, the device must be completely restarted.
•
Application error setting: In the event of an application error, all safety outputs
switch to the OFF state. Once the cause of the error has been rectified, the safety
function must be restarted.
Reset required
S
ignals that a reset is possible. A connected lamp lights up if the restart interlock has
been triggered and the protective field is then clear again.
Monitoring result
Indic
ates the status of the active field. A connected lamp lights up if an object is
detected in the field.
Reset required (flashing)
S
ignals that a reset is possible. A connected lamp flashes if the restart interlock has
been triggered and the protective field is then clear again.
7.11.2 Input signals
Static control input
S
ignal of the machine controller for switching between monitoring cases.
Evaluation methods: Complementary evaluation, 1-out-of-n evaluation
Parity evaluation (3 pins), P
arity evaluation (4 pins)
Signal of the machine controller for switching between monitoring cases.
Evaluation methods: Parity evaluation (odd, even)
External device monitoring (EDM)
S
ignal from the auxiliary contacts of the positively guided contactors for external device
monitoring (EDM).
Reset
S
ignal from the reset pushbutton to manually reset the internal restart interlock.
Sleep mode
S
ignal from a pushbutton to activate sleep mode.
Restart device
S
ignal from a pushbutton to completely restart the device.
Pause event recording
S
ignal of a pushbutton to stop the event history.
CONFIGURATION 7
8025919/1I9E/2023-01-09 | SICK O P E R A T I N G I N S T R U C T I O N S | safeVisionary2
71