9 Operation
9.1 Status indicators
Overview
OSSD1
OSSD2
LNK/ACT
DIAG
OSSD1
O
SSD2
LNK/ACT
DIAG
Figure 35: Status indicators
OSSD and DIAG status indicators
Table 36: OSSD and DIAG status indicators
LEDs Status
OSSD1 OSSD2 DIAG
O Gr
een O Green o
•
All pr
otective fields are clear
•
All configured OSSDs are ON
O R
ed O Red o
•
All c
onfigured OSSDs are OFF
•
No OSSDs configured
O Gr
een O Red o
OSSD pair 1 is ON, OSSD pair 2 is OFF
O R
ed O Green o
OSSD pair 1 is OFF, OSSD pair 2 is ON
Ö R
ed/
Yellow
o
Reset requested for OSSD pair 1
Ö R
ed/
Yellow
o
Reset requested for OSSD pair 2
O Gr
een or
red
O Green or
red
O Yellow
Object detected in the warning field
Ö Gr
een
The Ident
ify function has been selected in the con‐
figuration software. The device flashes so it can be
identified.
Ö / O
The warning and error indications of the DIAG LED
c
an be found under: "Fault indicators", page 84
o LED of
f. Ö LED flashes. O LED illuminates. Empty cells mean that the LED lights up, flashes, or is off.
Ethernet status displays
T
able 37: Ethernet status displays
LED
LNK/A
CT
Status
o
No Ethernet connection
O Gr
een
EtherCAT connection present, no data transmission
Ö Y
ellow
EtherCAT connection present, data is transmitted
o LED of
f. Ö LED flashes. O LED illuminates.
OPERATION 9
8025919/1I9E/2023-01-09 | SICK O P E R A T I N G I N S T R U C T I O N S | safeVisionary2
81
Subject to change without notice