6 Electrical installation
6.1 Connecting
Overview
T
he device is connected via the M12 plug connector.
Prerequisites
Mount
ing is completed.
Electrical installation is carried out according to the project planning.
Electrical installation is carried out according to the requirements for integration
into the electrical control system,
Dangerous condition of the machine is and remains off during the electrical instal‐
lation.
Outputs of the device have no effect on the machine during electrical installation.
Further topics
"Pr
oject planning", Seite 22
"Integrating the equipment into the electrical control", page 39
"Mounting", Seite 51
"Device overview", page 12
6.1.1 System connection
Prerequisites
Use shie
lded cables.
System connection M12, 8-pin
7
6
8
5
4
2
3
1
Figure 28: Male connector M12, 8-pin, A-coded
T
able 21: Pin assignment M12, 8-pin
PIN Designation Description
1 +24 VDC Supply voltage (24VDC)
2 OSSD1.A OSSD pair 1, OSSD A
3 0VDC Supply voltage (0VDC)
4 OSSD1.B OSSD pair 1, OSSD B
5 Uni I/O 1
U
niversal I/O 1, configurable
Static control input (B) together with pin 8
Parity evaluation 3pins (P3.2) together with pin 7
and 8
Parity evaluation 4pins (P4.2) together with pin 6, 7
and 8
6 OSSD2.A
U
ni-I/O 2
O
SSD pair 2, OSSD A
Universal I/O 2, configurable
Static control input (A1) together with pin 7
Parity evaluation 4pins (P4.1) together with pin 5, 7
and 8
ELECTRICAL INSTALLATION 6
8025919/1I9E/2023-01-09 | SICK O P E R A T I N G I N S T R U C T I O N S | safeVisionary2