7.11 Inputs and outputs, local
Overview
Y
ou will find an overview of the connections of the safety camera sensor on the Inputs
and outputs, local page.
Figure 32: Inputs and outputs, local
1
Pin assignment
2
Available signals
3
Remove signal from connection
4
Further settings for some signals
7.11.1 Output signals
OSSD
Dual-c
hannel, safety switching output which is used to switch off the dangerous state.
Contamination
S
ignals that the front screens are contaminated.
•
Partial contamination, optical covers should be cleaned soon (contamination warning). set‐
ting: The front screens should be cleaned soon.
•
Heavy contamination, device switches to the OFF state (contamination error). setting: All
safety outputs are in the OFF state. The front screens are heavily contaminated
and must be cleaned immediately.
7 C
ONFIGURATION
70
O P E R A T I N G I N S T R U C T I O N S | safeVisionary2 8025919/1I9E/2023-01-09 | SICK
Subject to change without notice