Detectable remission 4% … retroreflector (<330cd/Lux/sq.m) according to
t
ype 2, IEC61496-3
Maximum uniform contamination of
the front screens without reducing
the detection capability
20%
Zone of limited detection capability ≤50mm
Laser class 1 (IEC60825-1)
Resolution of the depth data 512px × 424px
Field of view 68° × 42° (protective field evaluation)
68° × 58°
(other field types and measurement data
acquisition)
Image repeatability rate 30Hz
1)
In the event of heavy contamination, the device displays a contamination error and switches all safety
out
puts to the OFF state.
Table 49: Measurement uncertainty
Remission 4%
(t
ypical)
Remission 100% (typical)
Scanning range 2m 2m 4m 8m
Statistical error (pixel) 1σ 12mm 2mm 2mm 5mm
Systematic error (absolute
v
alue)
20mm 20mm 20mm 40mm
13.2 Response time
Overview
The protective device’s response time is the maximum time between the occurrence of
the event leading to the sensor’s response and supply of the switch-off signal to the
protective device’s interface (for example OFF state of the OSSD pair).
In addition to the protective device’s response time, further signal transmission and
processing also influence the time up until the end of the dangerous state. This
includes a control’s processing time and the response times of downstream contactors,
for example.
Response time
T
able 50: Response time
Multiple sampling Response time in ms
1 55
2 89
3 123
4 157
5 191
6 225
7 259
8 293
9 327
10 361
11 395
12 429