User de
fined
You can adjust the settings for multiple sampling after switching between moni‐
t
oring cases in line with your requirements for the response time and reliability.
Regardless of the exact settings here, multiple sampling after switching between
monitoring cases is always at least one detection fewer than any other multiple
sampling in place: n
CS
≤ n – 1, min. 1.
Multiple sampling after object detection
Af
ter an object is detected, the protective field must be detected as unobstructed at
least four times in succession before the safety outputs switch back to the ON state.
If you activate the Activate different multiple sampling after object detection option, you can
specify alternate values for the monitoring level or for individual fields. This may cause
the outputs to switch back to the ON state faster or slower after a field has become free
again.
Further topics
"R
esponse time", page 93
"Protection from interference", page 24
7.10 3D editor
Overview
Figure 31: 3D editor
1
Toolbar
2
2D view
3
3D view
4
Main navigation: Mounting setting, Calibration data and Contours, Fields and ROI
5
Depending on the selected main navigation: Adjust the mounting settings, manage cali‐
br
ation data/contours, or configure fields/ROIs
CONFIGURATION 7
8025919/1I9E/2023-01-09 | SICK O P E R A T I N G I N S T R U C T I O N S | safeVisionary2
63
Subject to change without notice