Functions
8.18 Fail-safe functions
Control Units CU240S
8-134 Operating Instructions, 11/2006, A5E00766042B AA
Case 3: SLS monitoring > Frequency setpoint
Initiation of SLS =>
SLS monitoring activated
SLS-LED flashing
If frequeny setpoint falls below accuracy limit, an LSTO is triggered
immediately
Deactivation of SLS =>
SLS monitoring off
SLS-LED off
To start again, LSTO must be
acknowledged and a new on command
is necesarry to ramp up to frequency
setpoint.