HMI menu ID Parameter Description Default value
[unit]
value range Access
level
2.8.8.8 6th value Select the sixth value for the
view.
Totalizer 2
● Mass flow
● Volume flow
● Standard
volume flow
● Density
● Medium
temperature
● Fraction A
● Fraction B
● Fraction A %
● Fraction B %
User
2.8.8.9 Graph Scale Mode Select the scaling mode. Auto‐
matic scaling or fixed scaling us‐
ing “Graph Scale Lower Limit”
and “Graph Scale Upper Limit”.
Auto
● Auto
● Fixed
User
2.8.8.10 Graph log time window Select the logging period (time
axis length).
5 min
● 1 min
● 5 min
● 15 min
● 30 min
● 1 h
● 2 h
● 3 h
User
2.8.8.11 Graph Scale Lower Limit Define the scaling upper limit of
the value axis for fixed mode.
0 User
2.8.8.12 Graph Scale Upper Limit Define the scaling lower limit of
the value axis for fixed mode.
0 User
Table B-28 View 5
HMI menu ID Parameter Description Default value
[unit]
value range Access
level
2.8.9.1 Enable or disable Select whether the view is visi‐
ble.
Enabled
● Disable
● Enabled
User
2.8.9.2 View Select the view type. Three values
● Single value
● Three values
● One value and
bargraph
● One value and
graph
● Six values
● Six Diagnostic
values
User
Default settings
B.8 Local display
MASS 2100 & FC300 (FCT030)
416 Operating Instructions, 06/2017, A5E39789040-AA