HMI menu ID Parameter Description Default value
[unit]
Value range Access
level
4.2.9.2 Process values (1) Select the process values for
damping
Mass flow
Volume flow
Standard
volume flow
Standard
density
Totalizer 1
Totalizer 2
Totalizer 3
Dosing
Density
Medium
temperature
User
4.3 Modbus (channel 1)
4.3.1 Slave address (SW) Enter the device Modbus ad‐
dress. HW address device ad‐
dress overwrites the SW device
address.
1 1 to 247 User
4.3.2 Slave address (HW) Hardware device Modbus ad‐
dress. The HW device address
is configured by DIP switch in
the device.
Read
oSLy
4.3.3 Change Modbus param‐
eters
Changing Modbus parameters
needs restart communication
Cancel
Cancel
Ok
User
4.3.4 Data rate Select the data rate of your Mod‐
bus network.
19200 Bit/s
4800 Bit/s
9600 Bit/s
38400 Bit/s
57600 Bit/s
76800 Bit/s
115200 Bit/s
User
4.3.5 Parity and framing Select parity and stop bit config‐
uration.
Even parity, 1
stopbit
Even parity, 1
stopbit
Odd parity, 1
stopbit
No parity, 2
stopbits
User
4.3.6 Floating point byte order Select byte transmission se‐
quence
3-2-1-0
1-0-3-2
0-1-2-3
2-3-0-1
3-2-1-0
User
Default settings
B.13 Communication
MASS 2100 & FC300 (FCT030)
Operating Instructions, 06/2017, A5E39789040-AA 471