IO-Link Master
11.1 IO-Link Master (6ES7148-6JA00-0AB0)
ET 200eco PN
Operating Instructions, 08/2016, A5E01250250-AJ
215
Channel 7 Diagnostics: Short-circuit of
the sensor supply to M
• Disable
• Enable
Disable Channel group*
Diagnostics: Wire break
• Disable
• Enable
Disable Channel
Channel 0 Diagnostics: Short-circuit of
outputs to M
• Disable
• Enable
Disable Channel
Diagnostics: Wire break
• Disable
• Enable
Disable Channel
Channel 1 Diagnostics: Short-circuit of
outputs to M
• Disable
• Enable
Disable Channel
Diagnostics: Wire break
• Disable
• Enable
Disable Channel
Channel 2 Diagnostics: Short-circuit of
outputs to M
• Disable
• Enable
Disable Channel
Diagnostics: Wire break
• Disable
• Enable
Disable Channel
Channel 3 Diagnostics: Short-circuit of
outputs to M
• Disable
• Enable
Disable Channel
Diagnostics: Wire break
• Disable
• Enable
Disable Channel
* Channel group is defined by the digital inputs of the M12 socket. Example:
• Channel 4 and Channel 5 form the channel group of connection socket X5.
• Channel 6 and Channel 7 form the channel group of connection socket X7.
Generally short-circuit monitoring of the M12 digital input socket is only carried once via Pin 1 (1L+) and Pin 3 (1M). The
short-circuit parameterization can be used to select which channel of the M12 socket reports the short-circuit or whether
both channels report the short-circuit.