Safety notes
2.1 Notes on use
CPU 1515SP PC (F)
Manual, 05/2017, A5E32701806-AC
17
2.1 Notes on use
WARNING
Hazards at an unprotected machine or plant
According to the results of a risk analysis, hazards can occur at an unprotected machine.
The hazards may lead to personal injury.
According to the risk analysis, the risk of injury to persons can be countered with the
following measures:
Additional protective equipment at the machine or plant. In this case, the programming,
parameter assignment and wiring of the I/O used, in particular, must be performed in
accordance with the safety criteria (SIL, PL or Cat.) ascertained by means of an
appropriate risk analysis.
Use of the device for its intended purpose, which can be established by performing a
functional test on the plant. This allows errors in programming, parameter assignment
and wiring to be detected.
Documentation of the test results which can be entered, if required, into the relevant
safety certificates.
NOTICE
Ambient conditions
Ambient conditions for which the device is not suitable can lead to faults or damage the
device.
Note the following:
Only operate the device in enclosed areas. If you do not comply with this instruction, the
warranty becomes void.
Only operate the device in accordance with the ambient conditions given in the technical
specifications.
Protect the device from dust, moisture and heat.
Do not expose the device to direct sunlight or other strong sources of light.
The device must not be used in places with more difficult operating conditions through
corrosive vapors or gases without taking additional protective measures, for example,
supply of clean air.

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C

Related product manuals