Product overview
3.7 Scope of delivery
CPU 1515SP PC (F)
28 Manual, 05/2017, A5E32701806-AC
3.7
Scope of delivery
3.7.1
Unpacking the device
When unpacking
When unpacking, make sure to check the following:
Check packaging and contents for visible damage from transport.
Check the delivery for completeness.
Please inform your Siemens contact partner should you determine damages from
transport or any irregularities.
Keep the supplied documentation and licenses. They belong to the device and are the
proof that you have purchased the software preinstalled on the CFast card.
Documentation and licenses are required for initial commissioning and for any questions
that arise.
Keep the original packaging in case the device needs to be transported again.
NOTICE
Damage to the device during transport and storage
If a device is transported or stored without packaging, it is unprotected from shocks,
vibrations, pressure and moisture. Damaged packaging indicates that environmental
conditions have already had a significant impact on the device.
The device might be damaged.
Do not dispose of the original packaging. Pack the device for transport and storage.
NOTICE
Damage to the device caused by condensation
If the device was exposed to low temperatures or extreme variations in temperature during
transport, this may cause moisture to build up on or in the device (condensation).
Moisture can cause short-circuits in the electrical circuits and damage the device.
Proceed as follows to avoid damage:
Store the device in dry conditions.
Make sure it adapts to room temperature before commissioning.
Do not expose the device to direct heat radiation from a heater.
If condensation has developed, wait for approximately 12 hours or until the device is
completely dry before you switch it on.

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C