Maintenance
9.2 Change partitioning
CPU 1515SP PC (F)
Manual, 05/2017, A5E32701806-AC
85
9.2
Change partitioning
9.2.1
Partitions in the delivery state
Partitioning the CFast card
The following partitions are set up on the CFast card by default:
Partition
Name
30 GB CFast card
(WES7 E 32Bit/WES7 P 64Bit)
File system
C:
SYSTEM
19.5 GB
NTFS
D: DATA 8 GB NTFS
-
-
0.4 GB
RAW
-
WinCCMB
0.04 GB
NTFS
Note
Partitions in Windows Embedded Standard 7
The partitions need to be set again if they are faulty or if the partitioning is to be changed.
NOTICE
CPU volume for software controller (0.4 GB RAW)
Do not change the CPU volume for software controllers.
This is the only way to ensure that the software controller continues to operate without
error.

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C

Related product manuals