Image processing
4.4 Options for image acquisition and image processing
SIMATIC MV420 / SIMATIC MV440
Operating Instructions, 04/2013, A5E02371045-06
89
Auto trigger with initial trigger and timeout
,PDJHDFTXLVLWLRQ
7ULJJHU
'HFRGLQJ
5HVXOWVWUDQVIHU
7ULJJHULQLWLDWHV
SURFHGXUH
7ULJJHUVLJQDO
LVLJQRUHG
7ULJJHULQLWLDWHV
SURFHGXUH
QRWIRXQG
2.
[
[[
1 Limit of the decoding time
2 Image acquisition time
3 Interval of image acquisition
4 Set timeout
Triggers after the procedure has started are ignored until the result has been transferred.
Figure 4-18 Time diagram auto trigger with initial trigger and timeout
Note
1 (limit of the decoding time) = 3 (interval of image acquisition)!
Number of acquired images = {(Timeout/Acquisition interval) - 1}