Image processing
4.4 Options for image acquisition and image processing
SIMATIC MV420 / SIMATIC MV440
90 Operating Instructions, 04/2013, A5E02371045-06
Auto trigger edge-triggered with timeout
,PDJHDFTXLVLWLRQ
7ULJJHU
'HFRGLQJ
5HVXOWVWUDQVIHU
5LVLQJWULJJHUHGJHLQLWLDWHV
SURFHGXUH
7ULJJHUVLJQDO
LVLJQRUHG
QRWIRXQG
2.
[
[[
[
1 Limit of the decoding time
2 Image acquisition time
3 Interval of image acquisition
4 Timeout
Rising trigger edges after the procedure has started are ignored until the result has been transferred.
Figure 4-19 Time diagram auto trigger with the edge-triggered start/stop option
Note
1 (limit of the decoding time) = 3 (interval of image acquisition)!
Number of acquired images = {(Timeout/Acquisition interval) - 1}