Technical data and characteristics
6.2 Data sheets and characteristics
1FN3 linear motors
226 Configuration Manual, 10/2018, 6SN1197-0AB86-0BP2
1FN3100-4NC80-0xAx
Technical data
Designation
Unit
Value
Secondary section cooling data
Maximum dissipated thermal output
Q
S,MAX
kW
0.0881
Recommended minimum volume flow rate
V
S,MIN
l/min
2.5
Pressure drop per meter of heatsink profile
Δp
S
bar
0.0393
Pressure drop per combi distributor
Δp
KV
bar
0.167
Pressure drop per coupling point
Δp
KS
bar
0.123