Mechanical installation
3.3 Mounting
Converter cabinet units
58 Operating Instructions, 07/2016, A5E03347396A
3. Options M43 and M54 only:
Use the sealing tape provided to attach the contact surfaces of the hood to the top of the
cabinet.
Figure 3-17 Hood with attached sealing tape
4. Place the washers of the original roof screws between the cabinet upper side and the
hood at the contact points of the cabinet front side. This prevents the hood from being
pressed down too far when the screws are tightened and so the opening of the doors
blocked.
Figure 3-18 Attaching the washers